An interactive tool for the evaluation of ECG visualisation formats (2013)
Presentation / Conference Contribution
Martin, E. S., Finlay, D. D., Nugent, C. D., Bond, R. R., & Breen, C. (2013, September). An interactive tool for the evaluation of ECG visualisation formats. Presented at Computing in Cardiology 2013, Zaragoza, Spain

Electrocardiograms are typically printed on graph paper. Based on these recordings clinicians look for changes in the various waveforms when they make a diagnosis. In some cases, however, these changes are not always obvious on the standard printed 1... Read More about An interactive tool for the evaluation of ECG visualisation formats.

P32 Does Disease Severity Affect Patient Activation Scores in COPD? (2012)
Presentation / Conference Contribution
Roberts, N., Patel, I., Kidd, L., Lawrence, M., & Booth, J. P32 Does Disease Severity Affect Patient Activation Scores in COPD?. Presented at British Thoracic Society winter meeting 2012, London

Background As part of the NHS Plan patients are encouraged to manage their own health. Healthcare professionals have a responsibility to ensure that patients have the right tools and education to self-manage their conditions. Hibbard et al have devel... Read More about P32 Does Disease Severity Affect Patient Activation Scores in COPD?.

P219 Gender Differences in GP Suggested Diagnosis For COPD in Primary Care (2012)
Presentation / Conference Contribution
Roberts, N., Patel, I., & Partridge, M. P219 Gender Differences in GP Suggested Diagnosis For COPD in Primary Care. Presented at British Thoracic Society winter meeting 2012, London

Background Mosca et al has shown that clinicians fail to recognise cardiovascular risk in women (1). We have explored whether the same applies to COPD.

Methods Gender, demographics and symptoms were examined for patients referred by a GP to a comm... Read More about P219 Gender Differences in GP Suggested Diagnosis For COPD in Primary Care.

Assessing perception of new methods that represent ST deviation (2012)
Journal Article
Bond, R., Finlay, D., Breen, C., Nugent, C., Guldenring, D., & Martin, E. (2012). Assessing perception of new methods that represent ST deviation. Journal of Electrocardiology, 45(6), 698. https://doi.org/10.1016/j.jelectrocard.2012.08.041

The ST Map is a new method to assess acute myocardial infarction (AMI). Although variations of the ST Map do exist, Philips Healthcare has been the first to integrate its approach into clinical practice. This study assessed student perception of the... Read More about Assessing perception of new methods that represent ST deviation.

The effects of electrode misplacement on clinicians’ interpretation of the standard 12-lead electrocardiogram (2012)
Journal Article
Bond, R., Finlay, D., Nugent, C., Breen, C., Guldenring, D., & Daly, M. (2012). The effects of electrode misplacement on clinicians’ interpretation of the standard 12-lead electrocardiogram. European Journal of Internal Medicine, 23(7), 610-615. https://doi.org/10.1016/j.ejim.2012.03.011

Introduction
This study investigates how a particular incorrect electrode configuration affects the 12-lead Electrocardiogram (ECG).

Methods
A correct and an incorrect 12-lead ECG were extracted from a 192-lead BSPM. This was done for 232 BSPMs... Read More about The effects of electrode misplacement on clinicians’ interpretation of the standard 12-lead electrocardiogram.

Evaluation of a direct access cardiac arrhythmia monitoring service (2012)
Journal Article
Skipsey, D. A., Dawson, F. M., Breen, C., & Leslie, S. J. (2012). Evaluation of a direct access cardiac arrhythmia monitoring service. Cardiology, 19(1), 70-75. https://doi.org/10.5603/CJ.2012.0010

Background: This paper describes the clinical outcomes from a novel direct access arrhythmia monitoring service.

Methods: The study was carried out in the north of Scotland. Data was collected over a 29 month period between 18 June 2008 and 8 Nov... Read More about Evaluation of a direct access cardiac arrhythmia monitoring service.

The utility of a 12-lead electrocardiogram electrode misplacement simulator in education (2011)
Journal Article
Bond, R., Finlay, D., Nugent, C., Moore, G., Breen, C., Wagner, G., & Guldenring, D. (2011). The utility of a 12-lead electrocardiogram electrode misplacement simulator in education. Journal of Electrocardiology, 44(6), 748. https://doi.org/10.1016/j.jelectrocard.2011.09.025

A standard 12-lead electrocardiogram (ECG) is recorded using 6 precordial electrodes and 3 limb electrodes, all of which are positioned at precise anatomical landmarks. Nevertheless, up to 4% of all 12-lead ECGs are recorded with incorrect electrode... Read More about The utility of a 12-lead electrocardiogram electrode misplacement simulator in education.

S12 Pre-clinic telephone consultations: a costing study (2010)
Presentation / Conference Contribution
O'Byrne, L., Roberts, N. J., Boyd, K., Briggs, A., & Partridge, M. R. S12 Pre-clinic telephone consultations: a costing study. Presented at British Thoracic Society Winter meeting, London

Study of the taking of a patients’ history by telephone prior to clinic attendance and co-ordinating investigations for new respiratory patients showed a reduction in hospital attendances with no detrimental impact on patients (ERS 2010). Health serv... Read More about S12 Pre-clinic telephone consultations: a costing study.

A smartphone based telemedicine system for recording limited lead body surface potential maps (2009)
Presentation / Conference Contribution
Finlay, D., Nugent, C., Breen, C., Bond, R., & Moore, G. (2009, September). A smartphone based telemedicine system for recording limited lead body surface potential maps. Presented at 2009 36th Annual Computers in Cardiology Conference (CinC), Utah, USA

In this paper we describe the development of a limited lead BSPM system which is based around a commercial 12-lead ECG acquisition unit and a smartphone. We repositioned the six precordial leads to allow for better information capture and hence more... Read More about A smartphone based telemedicine system for recording limited lead body surface potential maps.