Sol-air temperature and daylight illuminance profiles for the UKCP09 data sets. (2011)
Journal Article
Tham, Y. W., & Muneer, T. (2011). Sol-air temperature and daylight illuminance profiles for the UKCP09 data sets. Building and Environment, 46, 1243-1250. https://doi.org/10.1016/j.buildenv.2010.11.014

To provide information on climate change, the UK Climate Impacts Programme (UKCIP) provided the latest UKCP09data to a resolution of 5 km square grids for the UK. Those datasets were used in this study along with the historical measured data for two... Read More about Sol-air temperature and daylight illuminance profiles for the UKCP09 data sets..

Thermal model for performance prediction of integrated collector storage systems (2011)
Journal Article
Garnier, C., Muneer, T., & Currie, J. (2011). Thermal model for performance prediction of integrated collector storage systems. Journal of Renewable and Sustainable Energy, 3, https://doi.org/10.1063/1.3549148

The result of many years of global research on solar water heating systems has outlined the promising approach of integrated collector storage solar water heaters (ICS-SWHs) in cold climates. This research paper aims to model the field performance of... Read More about Thermal model for performance prediction of integrated collector storage systems.

Inter-relationship between mean-daily irradiation and temperature, and decomposition models for hourly irradiation and temperature (2011)
Journal Article
Gago, E. J., Etxebarria, S., Tham, Y. W., Aldali, Y., & Muneer, T. (2011). Inter-relationship between mean-daily irradiation and temperature, and decomposition models for hourly irradiation and temperature. International Journal of Low-Carbon Technologies, 6, 22-37. https://doi.org/10.1093/ijlct/ctq039

Terrestrial temperature records have existed for centuries. These records are available for very many locations. Temperature is indeed the most widely measured meteorological parameter. In contrast, solar radiation being a parameter of secondary impo... Read More about Inter-relationship between mean-daily irradiation and temperature, and decomposition models for hourly irradiation and temperature.

The effect of transport on air quality in urban areas of Syria (2011)
Journal Article
Almasri, R., Muneer, T., & Cullinane, K. (2011). The effect of transport on air quality in urban areas of Syria. Energy Policy, 39, 3605-3611. https://doi.org/10.1016/j.enpol.2011.03.062

Statistics show that the number of cars per capita in Syria is still low, but that the figure has more than doubled since 2004. Syria also suffers from inadequate public transport provision, poor infrastructure and the absence of suitable traffic man... Read More about The effect of transport on air quality in urban areas of Syria.

Sustainable transport solution for a medium-sized town in Turkey—A case study. (2011)
Journal Article
Muneer, T., Celik, A. N., & Caliskan, N. (2011). Sustainable transport solution for a medium-sized town in Turkey—A case study. Sustainable Cities and Society SCC, 1, 29-37. https://doi.org/10.1016/j.scs.2010.08.004

The United Nations projects that 60% of the world's population will be living in urban areas by 2030. Cities account for 2% of the world's area but 75% of the world's energy consumption. For over a century, the automobile has offered affordable freed... Read More about Sustainable transport solution for a medium-sized town in Turkey—A case study..

Cutting vehicle emissions with regenerative braking (2010)
Journal Article
Clarke, P., Muneer, T., & Cullinane, K. (2010). Cutting vehicle emissions with regenerative braking. Transportation Research Part D: Transport and Environment, 15(3), 160-167. https://doi.org/10.1016/j.trd.2009.11.002

This paper presents an analysis of vehicle regenerative braking systems as a quick and relatively easy means of achieving higher overall fuel efficiency and lowering carbon emissions. The system involves the installation of an additional electric mot... Read More about Cutting vehicle emissions with regenerative braking.

Estimation of hourly averaged solar irradiation: evaluation of models. (2010)
Journal Article
Tham, Y. W., Muneer, T., & Davison, B. (2010). Estimation of hourly averaged solar irradiation: evaluation of models. Building Services Engineering Research and Technology, 31, 9-25. https://doi.org/10.1177/0143624409350547

Hourly solar radiation data are required in many building services applications. These are also reported in the Chartered Institution of Building Services Engineers Guides A & J. Data from 16 locations in the UK were used to evaluate the so called Li... Read More about Estimation of hourly averaged solar irradiation: evaluation of models..

Integrated collector storage solar water heater: temperature stratification (2009)
Journal Article
Garnier, C., Currie, J., & Muneer, T. (2009). Integrated collector storage solar water heater: temperature stratification. Applied Energy, 86, 1465-1469. https://doi.org/10.1016/j.apenergy.2008.12.009

An analysis of the temperature stratification inside an Integrated Collector Storage Solar Water Heater (ICS-SWH) was carried out. The system takes the form of a rectangular-shaped box incorporating the solar collector and storage tank into a single... Read More about Integrated collector storage solar water heater: temperature stratification.

Security assessment of importing solar electricity for the EU (2009)
Journal Article
Asif, M., Currie, J., Muneer, T., & Kubie, J. (2009). Security assessment of importing solar electricity for the EU. Journal of the Energy Institute, 82(2), 102-105. https://doi.org/10.1179/014426009x394008

Prosperity in any society is subject to an adequate and consistent provision of energy. It is crucial to adopt an energy strategy with least dependence on vulnerable energy supply channels such as imported oil from foreign/overseas countries. The p... Read More about Security assessment of importing solar electricity for the EU.

Modelling bulk water temperature in integrated collector storage systems (2008)
Journal Article
Currie, J., Garnier, C., Muneer, T., Grassie, T., & Henderson, D. (2008). Modelling bulk water temperature in integrated collector storage systems. Building Services Engineering Research and Technology, 29, 203-218. https://doi.org/10.1177/0143624408094277

A simple low cost Integrated Collector Storage Solar Water Heater (ICS-SWH) was proposed for simulation in Scottish weather conditions. The system takes the form of a rectangular-shaped design incorporating the solar collector and storage tank into a... Read More about Modelling bulk water temperature in integrated collector storage systems.

Finite Volume Computational Fluid Dynamics Package for Solving Convective Heat Transfer Cases (2008)
Journal Article
Junaidi, H., Henderson, D., Grassie, T., Currie, J., & Muneer, T. (2008). Finite Volume Computational Fluid Dynamics Package for Solving Convective Heat Transfer Cases. International Journal of Mechanical Engineering Education, 36(2), 92-112. https://doi.

Computational fl uid dynamics (CFD) has brought a step change in the fi eld of fl ow analysis, particularly in the areas of fl uid dynamics and heat transfer, which are intertwined. It has carved a niche in applications where, a decade back, experi... Read More about Finite Volume Computational Fluid Dynamics Package for Solving Convective Heat Transfer Cases.

Models for the estimation of building integrated photovoltaic systems in urban environments (2008)
Journal Article
Clarke, P., Muneer, T., Davidson, A., & Kubie, J. (2008). Models for the estimation of building integrated photovoltaic systems in urban environments. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 222(1), 61-

Growing concerns of global warming has spurred a rapid growth in micro-renewable technologies. Technologies, which can be integrated into building structures, such as photovoltaic and solar thermal systems, are a popular choice with clients and insta... Read More about Models for the estimation of building integrated photovoltaic systems in urban environments.

The role of renewable and non-renewable sources for meeting future UK energy needs (2007)
Journal Article
Asif, M., Currie, J., & Muneer, T. (2007). The role of renewable and non-renewable sources for meeting future UK energy needs. International Journal of Nuclear Governance, Economy and Ecology, 1, 372-383. https://doi.org/10.1504/IJNGEE.2007.016657

Provision of sufficient, affordable and secure energy is very crucial for modern economies. Countries across the world are facing energy challenges one way or the other. This article discusses the present energy scenario of the UK and the emerging ch... Read More about The role of renewable and non-renewable sources for meeting future UK energy needs.

Comparison of aluminium and stainless steel built-in storage solar water heater (2007)
Journal Article
Asif, M., Currie, J., & Muneer, T. (2007). Comparison of aluminium and stainless steel built-in storage solar water heater. Building Services Engineering Research and Technology, 28, 293-303. https://doi.org/10.1177/0143624407082390

This article provides the results and findings of an experimental work undertaken in Pakistan that aimed to compare the performance of stainless steel and aluminium make built-in-storage solar waters. The experimental work undertaken as part of this... Read More about Comparison of aluminium and stainless steel built-in storage solar water heater.

Experimental and CFD Investigation of an ICSSWH at various inclinations. (2007)
Journal Article
Henderson, D., Junaidi, H., Muneer, T., Grassie, T., & Currie, J. (2007). Experimental and CFD Investigation of an ICSSWH at various inclinations. Renewable and Sustainable Energy Reviews, 11, 1087-1116. https://doi.org/10.1016/j.rser.2005.11.003

The integrated collector storage (ICS) is the type of solar water heater that has retained its existance for well over a century. The flat absorber plate ICS collector type is a relatively recent addition. Being effective, low cost and simple to manu... Read More about Experimental and CFD Investigation of an ICSSWH at various inclinations..

Evaluation of a new photodiode sensor for measuring global and diffuse irradiance, and sunshine duration. (2007)
Journal Article
Wood, J., Muneer, T., & Kubie, J. (2007). Evaluation of a new photodiode sensor for measuring global and diffuse irradiance, and sunshine duration. Journal of Solar Energy Engineering, 125, 1-6. https://doi.org/10.1115/1.1531149

A new integrated device (called the BF3) has been developed, which enables the simultaneous measurement of horizontal global and diffuse irradiance as well as sunshine presence at any time. The sensor needs no specific polar alignment or routine adju... Read More about Evaluation of a new photodiode sensor for measuring global and diffuse irradiance, and sunshine duration..

An investigation of possible improvements in accuracy of regressions between diffuse and global solar irradiation. (2007)
Journal Article
Clarke, P., Munawwar, S., Davidson, A., Muneer, T., & Kubie, J. (2007). An investigation of possible improvements in accuracy of regressions between diffuse and global solar irradiation. Building Service Engineering Research and Technology, 28, 189-197. https://doi.org/10.1177/0143624407076907

Horizontal hourly and sub-hourly diffuse and beam irradiance are required for the estimation of global irradiance on a given tilted surface. This information is used by engineers and architects for various solar energy applications and also to calcul... Read More about An investigation of possible improvements in accuracy of regressions between diffuse and global solar irradiation..

Modelling of flow rate in a photovoltaic-driven roof slate-based solar ventilation air preheating system. (2006)
Journal Article
Odeh, N. A., Grassie, T., Henderson, D., & Muneer, T. (2006). Modelling of flow rate in a photovoltaic-driven roof slate-based solar ventilation air preheating system. Energy Conversion and Management, 47, 909-925. https://doi.org/10.1016/j.enconman.2005.06.005

This paper describes the modelling of flow rate in a photovoltaic (PV) driven, roof slate based solar system for preheating ventilation air in cold climates. The system consists of a photovoltaic driven, attic mounted fan, which draws air through the... Read More about Modelling of flow rate in a photovoltaic-driven roof slate-based solar ventilation air preheating system..

Improved accuracy models for hourly diffuse solar radiation. (2006)
Journal Article
Muneer, T., & Munawwar, S. (2006). Improved accuracy models for hourly diffuse solar radiation. Journal of Solar Energy Engineering, 128, 104-117. https://doi.org/10.1115/1.2148972

Solar energy applications require readily available, site-oriented, and long-term solar data. However, the frequent unavailability of diffuse irradiation, in contrast to its need, has led to the evolution of various regression models to predict it fr... Read More about Improved accuracy models for hourly diffuse solar radiation..

Life cycle assessment of a medium-sized photovoltaic facility at a high latitude location (2006)
Journal Article
Muneer, T., Younes, S., Lambert, N., & Kubie, J. (2006). Life cycle assessment of a medium-sized photovoltaic facility at a high latitude location. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 220(6), 517-52

Performance of a 160 m 2 photovoltaic installation at the Napier University's Merchiston Campus, situated 3 km from Edinburgh's city centre, is presented. The alternative current and direct current electrical outputs have been recorded since the inst... Read More about Life cycle assessment of a medium-sized photovoltaic facility at a high latitude location.