Skip to main content

Research Repository

Advanced Search

Modeling fomite‐mediated SARS‐CoV‐2 exposure through personal protective equipment doffing in a hospital environment

King, Marco?Felipe; Wilson, Amanda M.; Weir, Mark H.; L�pez?Garc�a, Mart�n; Proctor, Jessica; Hiwar, Waseem; Khan, Amirul; Fletcher, Louise A.; Sleigh, P. Andrew; Clifton, Ian; Dancer, Stephanie J.; Wilcox, Mark; Reynolds, Kelly A.; Noakes, Catherine J.

Authors

Marco?Felipe King

Amanda M. Wilson

Mark H. Weir

Mart�n L�pez?Garc�a

Jessica Proctor

Waseem Hiwar

Amirul Khan

Louise A. Fletcher

P. Andrew Sleigh

Ian Clifton

Mark Wilcox

Kelly A. Reynolds

Catherine J. Noakes



Abstract

Self-contamination during doffing of personal protective equipment (PPE) is a concern for healthcare workers (HCW) following SARS-CoV-2-positive patient care. Staff may subconsciously become contaminated through improper glove removal; so, quantifying this exposure is critical for safe working procedures. HCW surface contact sequences on a respiratory ward were modeled using a discrete-time Markov chain for: IV-drip care, blood pressure monitoring, and doctors’ rounds. Accretion of viral RNA on gloves during care was modeled using a stochastic recurrence relation. In the simulation, the HCW then doffed PPE and contaminated themselves in a fraction of cases based on increasing caseload. A parametric study was conducted to analyze the effect of: (1a) increasing patient numbers on the ward, (1b) the proportion of COVID-19 cases, (2) the length of a shift, and (3) the probability of touching contaminated PPE. The driving factors for the exposure were surface contamination and the number of surface contacts. The results simulate generally low viral exposures in most of the scenarios considered including on 100% COVID-19 positive wards, although this is where the highest self-inoculated dose is likely to occur with median 0.0305 viruses (95% CI =0–0.6 viruses). Dose correlates highly with surface contamination showing that this can be a determining factor for the exposure. The infection risk resulting from the exposure is challenging to estimate, as it will be influenced by the factors such as virus variant and vaccination rates.

Journal Article Type Article
Acceptance Date Sep 18, 2021
Online Publication Date Oct 24, 2021
Publication Date 2022-01
Deposit Date Nov 4, 2021
Publicly Available Date Nov 4, 2021
Journal Indoor Air
Print ISSN 0905-6947
Electronic ISSN 1600-0668
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 32
Issue 1
Article Number e12938
DOI https://doi.org/10.1111/ina.12938
Keywords COVID-19, hospital infection model, PPE, quantitative microbial risk assessment, SA4RS CoV-2, surface-contact transmission
Public URL http://researchrepository.napier.ac.uk/Output/2819149

Files

Modeling fomite-mediated SARS-CoV-2 exposure through personal protective equipment doffing in a hospital environment (1.2 Mb)
PDF

Publisher Licence URL
http://creativecommons.org/licenses/by/4.0/

Copyright Statement
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.




You might also like



Downloadable Citations