Abstract

The present study involved performing an experiment to clarify whether vibration measurement values on the tool handle, in accordance with ISO 5349-1, can assess risk from workplace environments. The study investigated the relationship between the vibration magnitude of a handheld electric drill with different operating postures. The experiment included the determination of the participant’s temporary threshold shift (TTS) of vibrotactile perception threshold (VPT) at the tip of the index finger. The experimental hypothesis was that the vibration measurement values on the tool handle, in accordance with the ISO 5349-1 standard, include the effect of posture on the vibration measurements obtained despite the variation in posture and test participants. The hand-transmitted vibration (HTV) was applied using a hand-held electric drill applied to a pre-cast concrete paving slab substrate (600 × 600 × 50 mm, 55 MPa) using a 10 mm diameter masonry drill bit (without hammer action). The tool was operated using the right hand on twelve male subjects with three working postures (n= 36). Vibration was measured in three orthogonal directions according to the international standard ISO 5349-1 procedure. Vibration magnitudes were expressed as root-mean-square (r.m.s.) acceleration, frequency-weighted using the Wh frequency weighting. Clause 4.3 states that the characterisation of the vibration exposure is assessed from the acceleration of the surface in contact with the hand as the primary quantity. The experimental results indicate that the TTS following vibration exposure is not related to the measured vibration magnitude on the tool handle. Therefore, the automatic inclusion of posture and test participant variation is not proven. The results suggest that the vibration measurement values on the tool handle do not predict the TTS after hand-transmitted vibration in varying posture across the test participants. The research concludes that tool handle vibration measurement, in accordance with ISO 5349-1, does not properly assess the potential hazard from authentic workplace tool usage conditions of varying postures.

Citation

Taylor, M., Maeda, S., & Miyashita, K. (2021). An Investigation of the Effects of Drill Operator Posture on Vibration Exposure and Temporary Threshold Shift of Vibrotactile Perception Threshold. Vibration, 4(2), 395-405. https://doi.org/10.3390/vibration4020025

Journal Article Type Article
Acceptance Date Apr 11, 2021
Online Publication Date May 3, 2021
Publication Date 2021-06
Deposit Date Apr 22, 2021
Publicly Available Date May 3, 2021
Journal Vibration
Publisher MDPI
Peer Reviewed Peer Reviewed
Volume 4
Issue 2
Pages 395-405
DOI https://doi.org/10.3390/vibration4020025
Keywords hand-arm vibration, posture; vibrotactile perception
Public URL http://researchrepository.napier.ac.uk/Output/2763955
Publisher URL https://www.mdpi.com/journal/vibration

Files

An Investigation Of The Effects Of Drill Operator Posture On Vibration Exposure And Temporary Threshold Shift Of Vibrotactile Perception Threshold (1 Mb)
PDF

Publisher Licence URL
http://creativecommons.org/licenses/by/4.0/

Copyright Statement
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.








Related Outputs



You might also like



Downloadable Citations