Skip to main content

Research Repository

Advanced Search

Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital

Amran, Mohd Effendi; Muhtazaruddin, Mohd Nabil; Bani, Nurul Aini; Kaidi, Hazilah Mad; Hassan, Mohamad Zaki; Sarip, Shamsul; Muhammad-Sukki, Firdaus

Authors

Mohd Effendi Amran

Mohd Nabil Muhtazaruddin

Nurul Aini Bani

Hazilah Mad Kaidi

Mohamad Zaki Hassan

Shamsul Sarip



Abstract

This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.

Journal Article Type Article
Acceptance Date Jul 3, 2019
Publication Date 2019-12
Deposit Date Nov 24, 2020
Publicly Available Date Nov 25, 2020
Journal Bulletin of electrical engineering and informatics
Print ISSN 2089-3191
Electronic ISSN 2302-9285
Publisher Universitas Ahmad Dahlan
Peer Reviewed Peer Reviewed
Volume 8
Issue 4
Pages 1180-1188
DOI https://doi.org/10.11591/eei.v8i4.1624
Keywords Artificial bee colony (ABC), Distributed Generation (DG), Green building rating system (GBRS), Maximum demand (MD), Photovoltaic-type DG (PV-DG), Renewable energy (RE)
Public URL http://researchrepository.napier.ac.uk/Output/2703053
Publisher URL https://beei.org/index.php/EEI/article/view/1624

Files

Optimal Distributed Generation In Green Building Assessment Towards Line Loss Reduction For Malaysian Public Hospital (933 Kb)
PDF

Publisher Licence URL
http://creativecommons.org/licenses/by-nc/4.0/

Copyright Statement
Published under a Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) license.




You might also like



Downloadable Citations