Skip to main content

Research Repository

Advanced Search

Outputs (20)

An innovative approach for the passive cooling of batteries: An empirical investigation of copper deposition on polyurethane foam for the enhancement of phase change material (2024)
Journal Article
Alcock, K. M., Shearer, N., Santos, F. V., Cai, Z., & Goh, K. (2024). An innovative approach for the passive cooling of batteries: An empirical investigation of copper deposition on polyurethane foam for the enhancement of phase change material. Applied M

A proof-of-concept utilising Copper-Plated Polyurethane Foam (CPPF) and Phase Change Material (PCM) for passive thermal management of lithium-ion batteries is demonstrated in this study. The aim of this research is to assess the effectiveness of CPPF... Read More about An innovative approach for the passive cooling of batteries: An empirical investigation of copper deposition on polyurethane foam for the enhancement of phase change material.

Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Load Variations (2024)
Journal Article
Bonet-Jara, J., Fernandez-Cavero, V., Vedreno-Santos, F., Morinigo-Sotelo, D., & Pons-Llinares, J. (in press). Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Load Variations. IEEE Transactions on Indust

Induction motors work under steady-state in many applications. Nevertheless, in some cases they experience periodic load fluctuations, which generate constant frequency harmonics close to variable frequency bar breakage harmonics. In these cases, tim... Read More about Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Load Variations.

Individual Cell-Level Temperature Monitoring of a Lithium-Ion Battery Pack (2023)
Journal Article
Alcock, K. M., González-Vila, Á., Beg, M., Vedreño-Santos, F., Cai, Z., Alwis, L. S. M., & Goh, K. (2023). Individual Cell-Level Temperature Monitoring of a Lithium-Ion Battery Pack. Sensors, 23(9), Article 4306. https://doi.org/10.3390/s23094306

The work described herein details the deployment of an optical fibre strand with five fibre Bragg grating (FBG) sensors for individual cell-level temperature monitoring of a three-cell lithium-ion battery pack. A polymer guide tube with 3D printed pl... Read More about Individual Cell-Level Temperature Monitoring of a Lithium-Ion Battery Pack.

Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Arbitrary Load Variations (2022)
Presentation / Conference Contribution
Bonet-Jara, J., Fernandez-Cavero, V., Vedreno Santos, F., & Pons-Llinares, J. (2022). Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Arbitrary Load Variations. In 2022 International Conference on Elect

Induction motors work under steady state in many applications. Nevertheless, in some cases (e.g., wood cutting machine or pulp mixer in paper industries), the load continuously varies. In these cases, time-frequency transforms are needed to detect th... Read More about Very Accurate Time-Frequency Representation of Induction Motors Harmonics for Fault Diagnosis Under Arbitrary Load Variations.

Performance of Superconducting Generators with Different Topologies under Fault Conditions (2019)
Presentation / Conference Contribution
Guan, Y., Vedreno Santos, F., Azar, Z., Thomas, A., Li, G., Odavic, M., & Zhu, Z. Performance of Superconducting Generators with Different Topologies under Fault Conditions. Presented at The 9th International Conference on Power Electronics, Machines and

This paper compares the short-circuit performance of superconducting (SC) generators with three different topologies, i.e., iron-cored stator and rotor, iron-cored stator and air-cored rotor, and air-cored stator and rotor. The analysis is based on t... Read More about Performance of Superconducting Generators with Different Topologies under Fault Conditions.

Design considerations for high-power converters interfacing 10 MW superconducting wind power generators (2017)
Journal Article
Vedreño Santos, F., Odavic, M., Guan, Y., Azar, Z., Thomas, A., Li, G., & Zhu, Z. (2017). Design considerations for high-power converters interfacing 10 MW superconducting wind power generators. IET Power Electronics, 10(12), 1461-1467. https://doi.org

The design of power electronic converters for the integration of wind generated power into the grid is more and more important due to a new class of Superconducting Generators (SG) with power ratings of up to 20 MW. High efficiency of power converter... Read More about Design considerations for high-power converters interfacing 10 MW superconducting wind power generators.

Comparison of Electromagnetic Performance of 10-MW Superconducting Generators With Different Topologies for Offshore Direct-Drive Wind Turbines (2017)
Journal Article
Guan, Y., Zhu, Z. Q., Azar, Z., Thomas, A. S., Vedreño-Santos, F., Li, G., & Odavic, M. (2017). Comparison of Electromagnetic Performance of 10-MW Superconducting Generators With Different Topologies for Offshore Direct-Drive Wind Turbines. IEEE Transact

This paper compares the electromagnetic performance of 10MW superconducting (SC) generators with three different topologies, i.e., iron-cored stator and rotor (ISIRT), iron-cored stator and air-cored rotor (ISART), and air-cored stator and rotor (ASA... Read More about Comparison of Electromagnetic Performance of 10-MW Superconducting Generators With Different Topologies for Offshore Direct-Drive Wind Turbines.

Influence of pole number and stator outer diameter on volume, weight and cost of superconducting generator with iron-cored rotor topology for wind turbines. (2017)
Journal Article
Guan, Y., Zhu, Z. Q., Li, G., Azar, Z., Thomas, A. S., Vedreño-Santos, F., & Odavic, M. (2017). Influence of pole number and stator outer diameter on volume, weight and cost of superconducting generator with iron-cored rotor topology for wind turbines. I

This paper investigates the influence of pole number and stator outer diameter on the performance of superconducting (SC) generators. The SC generator has an iron-cored rotor topology. Firstly, the generator structure is introduced and the optimizati... Read More about Influence of pole number and stator outer diameter on volume, weight and cost of superconducting generator with iron-cored rotor topology for wind turbines..

Comparison of Peak Armature and Field Winding Currents for Different Topologies of 10-MW Superconducting Generators Under Short-Circuit Conditions (2016)
Journal Article
Guan, Y., Vedreno-Santos, F., Li, G. J., Azar, Z., Thomas, A. S., Li, G., …Zhu, Z. Q. (2016). Comparison of Peak Armature and Field Winding Currents for Different Topologies of 10-MW Superconducting Generators Under Short-Circuit Conditions. IEEE Transa

This paper studies the peak armature and peak field winding currents for three different topologies of 10 MW partial High Temperature Superconducting Generators (HTSGs) under Short-Circuit Conditions (SCC) by simulation. The investigated partial HTSG... Read More about Comparison of Peak Armature and Field Winding Currents for Different Topologies of 10-MW Superconducting Generators Under Short-Circuit Conditions.

Diagnosis of Rotor and Stator Asymmetries in Wound-Rotor Induction Machines Under Nonstationary Operation Through the Instantaneous Frequency (2014)
Journal Article
Vedreno-Santos, F., Riera-Guasp, M., Henao, H., Pineda-Sanchez, M., & Puche-Panadero, R. (2014). Diagnosis of Rotor and Stator Asymmetries in Wound-Rotor Induction Machines Under Nonstationary Operation Through the Instantaneous Frequency. IEEE Transactio

This paper proposes a methodology to improve the reliability of diagnosis of different types of faults in wound-rotor induction generators which work under variable load conditions, as in wind turbine applications; the method is based on the extracti... Read More about Diagnosis of Rotor and Stator Asymmetries in Wound-Rotor Induction Machines Under Nonstationary Operation Through the Instantaneous Frequency.