Y. Guan
Performance of Superconducting Generators with Different Topologies under Fault Conditions
Guan, Y.; Vedreno Santos, Francisco; Azar, Ziad; Thomas, A.S.; Li, G.J.; Odavic, M.; Zhu, Z.Q.
Authors
Dr Francisco Vedreno Santos F.VedrenoSantos@napier.ac.uk
Lecturer
Ziad Azar
A.S. Thomas
G.J. Li
M. Odavic
Z.Q. Zhu
Abstract
This paper compares the short-circuit performance of superconducting (SC) generators with three different topologies, i.e., iron-cored stator and rotor, iron-cored stator and air-cored rotor, and air-cored stator and rotor. The analysis is based on three-phase short-circuit fault, and finite element analysis is used for simulation. Following the introduction of specifications of generators, the short-circuit performances of different topologies are analyzed and compared, with the field winding excited by voltage and current excitation sources, respectively. It shows that the short-circuit performance can be improved by limiting the field current.
Citation
Guan, Y., Vedreno Santos, F., Azar, Z., Thomas, A., Li, G., Odavic, M., & Zhu, Z. (2018, April). Performance of Superconducting Generators with Different Topologies under Fault Conditions. Presented at The 9th International Conference on Power Electronics, Machines and Drives (PEMD 2018), Liverpool, UK
Presentation Conference Type | Conference Paper (published) |
---|---|
Conference Name | The 9th International Conference on Power Electronics, Machines and Drives (PEMD 2018) |
Start Date | Apr 17, 2018 |
End Date | Apr 19, 2018 |
Acceptance Date | Apr 17, 2018 |
Online Publication Date | May 31, 2019 |
Publication Date | Jun 17, 2019 |
Deposit Date | May 1, 2018 |
Publicly Available Date | Oct 16, 2020 |
Electronic ISSN | 2051-3305 |
Publisher | Institution of Engineering and Technology (IET) |
Peer Reviewed | Peer Reviewed |
Volume | 2019 |
Issue | 17 |
Pages | 4090-4095 |
DOI | https://doi.org/10.1049/joe.2018.8183 |
Keywords | fault condition; HTS; short-circuit; superconducting generator |
Public URL | http://researchrepository.napier.ac.uk/Output/1169547 |
Related Public URLs | https://events.theiet.org/pemd/ |
Files
Performance Of Superconducting Generators With Different Topologies Under Fault Conditions (published version)
(3.6 Mb)
PDF
Publisher Licence URL
http://creativecommons.org/licenses/by/3.0/
Copyright Statement
This is an open access article published by the IET under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/).
You might also like
Diagnosis of induction machines under non-stationary conditions: Concepts and tools
(2013)
Presentation / Conference Contribution
Diagnosis of induction machines under non-stationary conditions by means of the spectral filter
(2013)
Presentation / Conference Contribution
Diagnosis of eccentricity in induction machines working under fluctuating load conditions, through the instantaneous frequency
(2012)
Presentation / Conference Contribution
Vibration transient detection of broken bars by PSH sidebands
(2012)
Presentation / Conference Contribution
Diagnosis of rotor asymmetries in wound rotor induction generators operating under varying load conditions via the Wigner-Ville Distribution
(2012)
Presentation / Conference Contribution
Downloadable Citations
About Edinburgh Napier Research Repository
Administrator e-mail: repository@napier.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search