Abstract

To assess whether the Entropy Module (GE Healthcare, Helsinki, Finland), a device to measure hypnosis in anesthesia, is a valid measure of sedation state in critically ill patients by comparing clinically assessed sedation state with Spectral Entropy Prospective observational study. Teaching hospital general ICU. 30 intubated, mechanically ventilated patients without primary neurological diagnoses or drug overdose receiving continuous sedation. Monitoring of EEG and fEMG activity via forehead electrodes for up to 72 h and assessments of conscious level using a modified Ramsay Sedation Scale. 475 trained observer assessments were made and compared with concurrent Entropy numbers. Median State (SE) and Response (RE) Entropy values decreased as Ramsay score increased, but wide variation occurred, especially in Ramsay 4–6 categories. Discrimination between different sedation scores [mean (SEM) PK value: RE 0.713 (0.019); SE 0.710 (0.019)] and between lighter (Ramsay 1–3) vs.deeper (Ramsay 4–6) sedation ranges was inadequate [PK: RE 0.750 (0.025); SE 0.748 (0.025)]. fEMG power decreased with increasing Ramsay score but was often significant even at Ramsay 4–6 states. Frequent “on–off” effects occurred for both RE and SE, which were associated with fEMG activity.Values switched from low to high values even in deeply sedated patients. High Entropy values during deeper sedation were strongly associated with simultaneous high relative fEMG powers. Entropy of the frontal EEG does not discriminate sedation state adequately for clinical use in ICU patients. Facial EMG is a major confounder in clinical sedation ranges

Citation

Walsh, T. S., Ramsay, P., Lapinlampi, T. P., Särkelä, M. O. K., Viertiö-Oja, H. E., & Meriläinen, P. T. (2008). An assessment of the validity of spectral entropy as a measure of sedation statein mechanically ventilated critically ill patients. Intensive Care Medicine, 34(2), 308-315. https://doi.org/10.1007/s00134-007-0858-x

Journal Article Type Article
Acceptance Date Apr 4, 2007
Online Publication Date Sep 27, 2007
Publication Date 2008-02
Deposit Date Nov 8, 2018
Journal Intensive Care Medicine
Print ISSN 0342-4642
Electronic ISSN 1432-1238
Publisher BMC
Peer Reviewed Peer Reviewed
Volume 34
Issue 2
Pages 308-315
DOI https://doi.org/10.1007/s00134-007-0858-x
Keywords Sedation monitoring, electroencephalogram, critical illness, spectral entropy, sedatives